Abstract

Abstract A new pre-concentration/separation system coupled to a micro-hollow glow discharge (MHGD) plasma detector is demonstrated for the analysis of explosives. The detector and spectrometer are miniaturized and field-portable. Separation eliminated air interferences while pre-concentration improved detection limits for TATP (triacetone triperoxide) and DNT (dinitrotoluene). In the analysis step, a temperature ramp desorbed the two explosives into an entraining Ar flow. Optical emission spectroscopy (OES) was applied to detect the plasma generated atomic and diatomic radicals using a spectrometer at atmospheric pressure. For both test species, the detection limits reached values lower than 5 ppb. The effect of an at-sea environment was also evaluated. Such a detector system is very promising for the detection of explosives due its small size, high sensitivity and selectivity.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.