Abstract
A detailed study of essential ultra trace element of chromium present many of industrial waste lakes of western rajasthan. Aconvinent method of electroanlytical technique used for the essential trace element present in the industrial waste water as a polarography method for identification of essential trace element by using concentration of ppm to ppb. According to this method prepare solution of sodium chromate as a stock and identify electroanalytical potential by using as a supporting electrolyte 0.05 M HCl + 0.25 M NaCl give a sharp peak at ࡱ ൗ = 0.91(V) and result compare with other electroanalytical instrument like UV-Vis Sprctrophotometer, Atomic absorption spectroscopy
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal for Research in Applied Science and Engineering Technology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.