Abstract

This paper develops and analyzes an online methodology to detect demagnetization faults in surface-mounted permanent magnet synchronous motors. The proposed methodology, which takes into account the effect of the inverter that feeds the machine, is based on monitoring the zero-sequence voltage component of the stator phase voltages. The theoretical basis of the proposed method has been established. Attributes of the method presented here include simplicity, very low computational burden, and high sensibility. Since the proposed method requires access to the neutral point of the stator windings, it is especially useful when dealing with fault tolerant systems. A simple expression of the zero-sequence voltage component is deduced, which is proposed as a fault indicator parameter. Both simulation and experimental results presented in this paper show the potential of the proposed method to provide helpful and reliable data to carry out an online diagnosis of demagnetization failures in the rotor permanent magnets.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.