Abstract

We tested the accuracy of quenching probe-polymerase chain reaction (QP-PCR) for detecting Clostridioides difficile toxin B gene (tcdB) in stools from inpatients with suspected C. difficile infection and compared the results with other nucleic acid amplification tests (NAATs). Toxigenic culture results were used as reference for comparison. QP-PCR had comparable diagnostic accuracy with other NAATs and prior bead-beating enabled detection of tcdB in specimens judged as negative, without bead-beating. Taken together, the QP-PCR either with or without bead-beating showed sufficient effectiveness for detecting tcdB in stool specimens.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call