Abstract

Purpose To compare the diagnostic performance of a short dual-pulse sequence magnetic resonance (MR) imaging protocol versus a standard six-pulse sequence multiparametric MR imaging protocol for detection of clinically significant prostate cancer. Materials and Methods This HIPAA-compliant study was approved by the regional ethics committee. Between July 2013 and March 2015, 63 patients from a prospectively accrued study population who underwent MR imaging of the prostate including transverse T1-weighted; transverse, coronal, and sagittal T2-weighted; diffusion-weighted; and dynamic contrast material-enhanced MR imaging with a 3-T imager at a single institution were included in this retrospective study. The short MR imaging protocol image set consisted of transverse T2-weighted and diffusion-weighted images only. The standard MR imaging protocol image set contained images from all six pulse sequences. Three expert readers from different institutions assessed the likelihood of prostate cancer on a five-point scale. Diagnostic performance on a quadrant basis was assessed by using areas under the receiver operating characteristic curves, and differences were evaluated by using 83.8% confidence intervals. Intra- and interreader agreement was assessed by using the intraclass correlation coefficient. Transperineal template saturation biopsy served as the standard of reference. Results At histopathologic evaluation, 84 of 252 (33%) quadrants were positive for cancer in 38 of 63 (60%) men. There was no significant difference in detection of tumors larger than or equal to 0.5 mL for any of the readers of the short MR imaging protocol, with areas under the curve in the range of 0.74-0.81 (83.8% confidence interval [CI]: 0.64, 0.89), and for readers of the standard MR imaging protocol, areas under the curve were 0.71-0.77 (83.8% CI: 0.62, 0.86). Ranges for sensitivity were 0.76-0.95 (95% CI: 0.53, 0.99) and 0.76-0.86 (95% CI: 0.53, 0.97) and those for specificity were 0.84-0.90 (95% CI: 0.79, 0.94) and 0.82-0.90 (95% CI: 0.77, 0.94) for the short and standard MR protocols, respectively. Ranges for interreader agreement were 0.48-0.60 (83.8% CI: 0.41, 0.66) and 0.49-0.63 (83.8% CI: 0.42, 0.68) for the short and standard MR imaging protocols. Conclusion For the detection of clinically significant prostate cancer, no difference was found in the diagnostic performance of the short MR imaging protocol consisting of only transverse T2-weighted and diffusion-weighted imaging pulse sequences compared with that of a standard multiparametric MR imaging protocol. © RSNA, 2017 Online supplemental material is available for this article.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.