Abstract

We applied real-time broad-range polymerase chain reaction (PCR) to detect bacteraemia in blood from febrile patients. Interpretation of amplification results in relation to clinical data and blood culture outcome was complex, although the reproducibility of the PCR results was good. Sequencing analysis of the PCR products revealed the presence of Burkholderia species DNA while no Burkholderia species grew in culture. The source of this contamination was shown to be the commercial DNA isolation kit used in the automated MagNA Pure Isolation Robot. A high degree of suspicion is required when uncommon or unexpected pathogens are diagnosed by molecular methods as clinical consequences can be serious.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.