Abstract
This paper outlines an on-line condition-monitoring method for detecting arcing around the brush-commutator interface in DC motors. These motors are the critical components in steel-rolling mills, and tend to have excessive arcing and motor flashover under certain circumstances. The proposed method utilises system-identification and detection techniques. A parameter related to the arc-discharge voltage is estimated. This parameter is monitored for shift or drifts in its mean. Its mean value is different when the condition of the motor changes from no-arc to arcing. When this condition is detected, a warning is flagged to the mill operators. A prototype system has been implemented in one of BHP's steel-rolling mills for system evaluation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.