Abstract

PurposePostinsertion computed tomography (CT) can identify air gaps (AGs) around the cylinder in vaginal cuff brachytherapy (VCB). This study investigates the incidence and location of AGs. Methods and MaterialsPlanning CTs of 22 prospectively recruited patients (NCT02091050) treated with 2.6 cm (n = 8) and 3.0 cm (n = 14) cylinders were evaluated. In addition, a systematic literature review and meta-analysis was performed (PubMed and EMBASE). The pooled incidence of AGs was calculated by using the random-effects model weighted by inverse variance. ResultsIn 18 cases (82%), a total of 45 AGs were found: 26 within the 2 cm cranial length and 19 between 2 and 4 cm of the cylinder. The mean AG diameter was 3.7 mm (range: 1.3–11.8). Cylinder diameter, primary tumor site, and use of external beam radiotherapy were not associated with AG incidence. Systematic literature review revealed nine additional relevant studies, totaling 657 patients. The pooled incidence of patients with ≥1 AG was 67% (95% confidence interval: 50–83). AGs were located at the apex in 43.4%–94.4% of cases. In patients with ≥1 AG (n = 244), the pooled mean number of AGs was 2.18 per patient. The mean dose reduction varied from 9.6% to 29.3%. ConclusionMore than two-thirds of VCB cases present with AGs, which are most commonly at the apex and can potentially reduce mucosal dose. By identifying AGs, postinsertion CT can facilitate selection of optimal cylinder size in VCB.