Abstract

The aim of this study was to examine the importance of a transitional ion concentration zone at the apical foramen during electronic root canal length measurement (ERCLM). The model comprised 21 extracted single-rooted human teeth, divided into two experimental groups and one control group, each of seven teeth. The anatomical tooth length was determined from the site of reference on the tooth crown to the canal orifice and was measured using an endodontic file and a vernier caliper. Two aqueous solutions of various NaCl, KCl and CaCl2 concentrations were mixed with agar. The Na+, K+ and Ca++ concentrations corresponded to the average value of each group as determined by atomic spectrophotometry evaluation of the extirpated human pulps. The agar containing cations was injected into the root canals after their preparation to a foramen diameter of 0.70 mm. The control teeth were then completely immersed in agar having the same concentration of cations as the agar inside the canal. In the first experimental group (group 1), the teeth were immersed in agar so that the ion concentration was higher inside the canal; in the second experimental group (group 2), the concentrations were reversed. In all three groups, ERCLM was performed by an EED 11--resistance type device. Length d1 was defined as the length of the root when measured to a value one degree less than the test value. Length d2 was defined as the length of the root inducted by the test value, which corresponded to the resistance of the periapical agar. In group 1 the average d1 length was 0.44 +/- 1.05 shorter than the anatomical foramen (AF), and in group 2, 1.11 +/- 0.43 mm longer than AF. In the control group the d1 length was on average--3.02 +/- 3.72 mm from the AF. The d1 values of all groups were not statistically significantly different from the anatomical length (AL). In all three experimental groups the d2 length was statistically significantly different from the AL (P < 0.05, t-test); group 1 d2 = AL + 6.32 +/- 1.38 mm; group 2 d2 = AL + 6.27 +/- 1.47; control group d2 = AL + 9.15 +/- 1.00 mm. The results of this study indicated that when the electroconductive medium in the canal had a different ion concentration than the periapex, and the canal orifice had a wide diameter (0.70 mm), the transitional concentration zone influenced the accuracy of measurement during ERCLM with a resistance type device. When ion concentrations inside and outside the canal were identical, in teeth with a wide foramen diameter (0.70 mm or more) the lack of a transitional ion concentration zone meant that the length of the root canal could not be determined by ERCLM.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.