Abstract

A technique for detecting and measuring phase transitions in a multi-anvil apparatus by measuring the change in travel time for a longitudinal sound wave as a function of pressure is reported. The system measures the time for pulsed ultrasonic signals to travel through a high pressure assembly with a sample in the center. Upon phase change from liquid to solid, the travel time shows an abrupt decrease due to the intrinsic increase in velocity in the sample and a reduced delay between the triggering of an amplitude threshold and the arrival of the waveform. As a proof of concept, results are shown for mercury as it undergoes pressure-induced liquid ⇌ solid transitions at room temperature. We propose that this non-destructive technique may be valuable in situations where other in situ probing techniques cannot be readily used to provide information about changes of state and potentially to study transition kinetics at high pressures as well.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call