Abstract

For those people who are involved in NDE, there is a growing concern regarding the significant traveling distance of a guided wave in a structure, which ensures the inspection of a large area of the structure from a single location. A significant number of studies on the guided wave have therefore been made to apply the foregoing to a nondestructive evaluation in many different industries and resulted in an increase in the efficiency of practical guided wave inspection. Unlike the previous studies based mainly on the detection of circumferential flaws, this study is focused on the axial flaw detection in the steam generator tubes of Korean standard nuclear power plants by generating the guided wave by changing frequency and selecting the applicable mode from the dispersion curve for the steam generator tube calculated in this study, where the dispersion-based short-time Fourier transform (D-STFT) algorithm is used to enhance mode identification. In conclusion, the L (0,1) mode at 2.25MHz is found to be most sensitive in detecting axial flaws in a steam generator tube.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.