The AC interference on pipelines caused by nearby HVAC power lines and electrified railways can lead to electric shock hazard and AC corrosion, which threatens the safety of pipeline and has attracted more and more attention. A 300km-long pipeline in the north of China is close to many HVAC power lines and electrified railways and there exists a high risk of AC interference. A detection of AC interference has been done along the pipeline and the results indicate that AC interference is severe due to high AC voltage and AC current density. The mitigation scheme of the pipeline is designed with the aid of computer simulation software, based on which the mitigations are constructed. The field measurements show that the mitigation effect is good.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.