Abstract

The presence of electrical and mechanical faults in the induction motors (IMs) can be detected by analysis of the stator current spectrum. However, when an IM is fed by a frequency converter, the spectral analysis of stator current signal becomes difficult. For this reason, the monitoring must depend on multiple signatures in order to reduce the effect of harmonic disturbance on the motor-phase current. The aim of this paper is the description of a new approach for fault detection and diagnosis of IMs using signal-based method. It is based on signal processing and an unsupervised classification technique called the artificial ant clustering. The proposed approach is tested on a squirrel-cage IM of 5.5 kW in order to detect broken rotor bars and bearing failure at different load levels. The experimental results prove the efficiency of our approach compared with supervised classification methods in condition monitoring of electrical machines.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.