Abstract
Thirty-five patients scheduled to undergo a neck dissection for squamous cell carcinoma of the head and neck were evaluated preoperatively by magnetic resonance (MR) imaging. Axial and occasionally sagittal and coronal images were obtained. To define the most reliable technique to detect cervical lymph node metastasis, we compared several MR pulse sequences with and without Gd-DTPA administration to histopathologic findings in the neck dissection specimens. T1-weighted spin echo combined with T2-weighted gradient recalled echo (GE) sequences were found to be more useful than any other combination of pulse sequences in localizing lymph nodes. On T2-weighted GE images, lymph nodes were depicted with intermediate to high signal intensity in contrast to low signal muscular and fatty tissue. Gadolinium DTPA enhanced T1-weighted GE images reliably depict central lymph node necrosis, the most specific criterion for lymph node metastasis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.