Abstract

ObjectivesThe aims of this study were to detect the acetylcarnitine resonance line at 2.13 ppm in the human vastus lateralis and soleus muscles, assess T1 and T2 relaxation times, and investigate the diurnal and exercise-related changes in absolute concentration noninvasively, using proton magnetic resonance spectroscopy at 7 T.Materials and MethodsAll measurements were performed on a 7 T whole-body Magnetom MR system with a 28-channel knee coil. Five healthy, moderately trained volunteers participated in the assessment of the detectability, repeatability, and relaxation times of acetylcarnitine. For the evaluation of the effect of training status, another 5 healthy, normally active volunteers were examined. In addition, normally active volunteers underwent a day-long protocol to estimate diurnal changes and response to the exercise.ResultsUsing a long echo time of 350 milliseconds, we were able to detect the acetylcarnitine resonance line at 2.13 ppm in both muscle groups without significant lipid contamination. The T1 of acetylcarnitine in the vastus lateralis muscle was found to be 1807.2 ± 513.1 milliseconds and T2 was found to be 129.9 ± 44.9 milliseconds. Concentrations of acetylcarnitine from the vastus lateralis muscle in moderately trained volunteers were higher than concentrations from normally active volunteers. Acetylcarnitine concentrations changed during the day, tending to be higher in the morning after an overnight fast than after lunch. After 10 minutes of high-intensity exercise, the concentration significantly increased, and 15 minutes after cessation of exercise, a decrease could be observed.ConclusionsOur results demonstrate an effective detection of acetylcarnitine using a long TE of 350 milliseconds at 7 T in the vastus lateralis and soleus muscles with high repeatability and reliability on a 7 T scanner. Our data emphasize the need for strict standardization, physical activity, and dietary conditions for the measurement of the acetylcarnitine.

Highlights

  • ObjectivesThe aims of this study were to detect the acetylcarnitine resonance line at 2.13 ppm in the human vastus lateralis and soleus muscles, assess T1 and T2 relaxation times, and investigate the diurnal and exercise-related changes in absolute concentration noninvasively, using proton magnetic resonance spectroscopy at 7 T

  • Our results demonstrate an effective detection of acetylcarnitine using a long TE of 350 milliseconds at 7 T in the vastus lateralis and soleus muscles with high repeatability and reliability on a 7 T scanner

  • Our study demonstrated that acetylcarnitine could be detected by 1H MRS at 7 T in 2 different and, from the point of view of physiological research, very important skeletal muscle groups, SOL and vastus lateralis (VL)

Read more

Summary

Objectives

The aims of this study were to detect the acetylcarnitine resonance line at 2.13 ppm in the human vastus lateralis and soleus muscles, assess T1 and T2 relaxation times, and investigate the diurnal and exercise-related changes in absolute concentration noninvasively, using proton magnetic resonance spectroscopy at 7 T

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.