Abstract

DP-QAM is one of the feasible paths towards 100Gbps, 400Gbps and 1Tbps optical communications systems. For DPQAM transmitter, the time mismatch between the XY tributary channels is known as the XY skew. Large uncompensated XY skew can significantly degrade the system performance. Sometimes, time-interleaved return-to-zero DP signal is preferred with lower nonlinear polarization scattering induced penalty. In this work, XY skew detection and alignment of dual-polarization optical quadrature amplitude transmitter using reconfigurable interference is experimentally demonstrated with >23-dB dynamic range. ~1.5-dB power change is achieved for 1-ps XY skew. Fast detecting scheme for arbitrary skew measurement is also experimentally verified. The scheme is compatible with different modulation formats, data sequences, and waveforms.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.