In this article, a novel method to detect the partial demagnetization in air-cored permanent-magnet axial-flux generators is proposed. Its principle is to monitor a speed-normalized fault detection signal. This signal depends only on the demagnetization severity, as it was extracted using a flux-sensor with a span that negates the induced voltage under balanced conditions. The generator has been designed for marine renewable applications working under variable speed conditions rending PM health monitoring under nonstationary conditions imperative. Initially, a mathematical equation for the electromotive force is derived under partial demagnetization conditions with the aim to extract the frequency components related to the fault. To estimate the demagnetization severity, an approach was developed based on the magnetic flux monitoring, which penetrates throughout the sensor. A 3-D finiteelement model of the installed winding in the generator is employed to verify the proposed method under steady and variable speed conditions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.