Abstract

We suggest and compare two multiple change-point algorithms (segmentation and sequential) for accurate detection of the onset of abrupt leaks in blended underground storage tanks. We apply these algorithms to two simulated scenarios to demonstrate the advantages of the sequential algorithm, and then we apply the sequential algorithm to the Cary blended site data. In addition, we obtain a confidence set for the locations of the change points conditional on the number of change points by inverting the related hypothesis test.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.