Abstract
This paper is a study of the shear capacity of autoclaved aerated concrete lintels reinforced with unbonded bars. A set of tests was performed to measure the anchorage capacity of the beam ends with seven different configurations. Full lintels were also tested to failure under transverse loading for two steel details. The study of the test results confirms that the lintels fail in a brittle mode when the anchorage capacity of the longitudinal bars is reached. A steel detail producing a stiff truss action at the beam ends relieving the stresses on the concrete shows to be the best arrangement, increasing the strength of the beams and producing a relatively ductile failure.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.