Abstract

Detailed CFD models of mineral-insulated metal-sheathed (MIMS) thermocouples are discussed and thermocouple readings in fire environment are validated against experimental thermocouple data for a Hencken burner flame. Thermocouple readings are presented as functions of equivalence ratio, thermocouple diameter, thermocouple orientation, position of the junction, depth of insertion into fire, and sheath surface emissivity. Effects of surface oxidation, sheath diameter, and insertion depth on thermocouple response time are analyzed in detail. Computational results are compared with published experimental data. Overall, predictions showed excellent agreement with experimental data. Small deviations occurred in the case of insertion depths due to axial heat losses.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.