Abstract
Taking into consideration the latest design of the International Thermonuclear Experimental Reactor (ITER) main units, we have made the detailed design consideration for an ex-vessel neutron yield monitor to meet the ITER requirements. The monitoring system is constructed of four detector modules consisting of several U235 fission chambers with different sensitivities and graphite (or beryllium) neutron moderator. We also selected possible spaces in the diagnostic ports to install them at appropriate distances and neutron shielding effects from the plasma. Through Monte Carlo neutron transport calculations, it has been confirmed that the present system can cover all the neutron yields encountered in the ITER experiments including the in situ calibrations with a time resolution around 200 μs without detector replacement over the whole ITER experiments. This system can also be calibrated with 10% of required accuracies in a realistic 50 h of accumulation time using a DT neutron generator.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.