Abstract

In order to overcome the heavy casualties caused by gas explosion, we verified the propagation law of shock wave in pipeline and the overpressure distribution of gas explosion by similar experiments according to the analyses of reasons for casualty and ventilation system model destroyed by gas explosion in the mining face. We summarized the gas composition after the explosion and its danger, analyzed the effects of the gas explosion shock wave to ventilation system and facilities and the laws of toxic gas spread and diffusion in the ventilation network after the explosion. We presented a technical proposal to control the smoke and recover the ventilation system after a gas explosion and developed a reserve air door and control system that were embed in the lane, and could close automatically in conditions of no pressure and electricity. The results showed that the reserve air door normally opened and could close automatically controlling the smoke flow and resuming the ventilation system when the gas explosion shock wave destroyed the original shutting air door which resulted in the air short circuit.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call