Abstract

The monitoring of dissolved oxygen is a key parameter in many fields, namely the treatment and monitoring of various cerebral traumas. Leveraging existing manufacturing techniques, electrochemical sensors hold the potential for compact, simple, and scalable dissolved oxygen sensors. Past studies have focused on the general design of such sensors, but a comparative study on the impact of microelectrode geometries for cerebral applications has been forthcoming. We present here the results of a characterization study conducted across solid-state sensors with varying microelectrode geometries. The electrode structures were covered with a Nafion membrane and included variations of the classic interdigitated microelectrode array in addition to a circular microelectrode array variation. Voltage sweeps were conducted while monitoring the devices’ sensing current responses across a 50.3 mmHg change in dissolved oxygen within a deionized aqueous solution. Half of the devices were identified as ultramicroelectrode designs that presented a greater dependence on electrode spacing and topology. The ultramicroelectrode-style (UME) interdigitated electrode (IDE) topology presented the greatest signal response at 25.24 nA/mmHg, an approximate eight-fold improvement in sensitivity from a non-UME variation with a sensitivity of 2.98 nA/mmHg. The design presented a linear response from 8.3 mmHg to 58.6 mmHg with r2 = 0.9743. The sensitivity improvement was attributed to the ultramicroelectrode structure’s amplifying diffusive feedback, which was enabled by the IDE topology and short electrode spacings.

Highlights

  • Throughout ecological, biomedical, and chemical applications, the close monitoring of dissolved oxygen levels may prove critical during process control, environmental condition monitoring, and clinical diagnostics

  • Damage to living brain tissue caused by an external mechanical force necessitates invasive forms of surgery during which the close monitoring of brain tissue oxygen levels is paramount for preventing tissue hypoxia [3]

  • Dissolved oxygen concentration is a key parameter in monitoring processes for a wide array of industries and fields, and the optimized design of microelectrode-based oxygen sensors is critical for effective clinical applications

Read more

Summary

Introduction

Throughout ecological, biomedical, and chemical applications, the close monitoring of dissolved oxygen levels may prove critical during process control, environmental condition monitoring, and clinical diagnostics. In industry, this is useful for quality control in water production, as well as sewage management [1]. In clinical applications where reliability, accuracy, and biofunctionality are paramount, suitable dissolved oxygen sensors have proven immensely beneficial. One such clinical application is during neurological surgery for traumatic brain injuries (TBI).

Methods
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.