Abstract

ABSTRACT This contribution deals with the application of numerical methods in CPC-Systems' microreaction development process and demonstrates the feasibility and significant benefits for the suggested design method. It is focused on the design of capillary residence tubes, which is necessary if the residence time provided by the original microreactor is not sufficient to complete the reaction. The residence time distribution is calculated from a straightforward numerical model based on the common assumption that axial gradients can be neglected. The results can be adapted easily to other capillary diameters or reaction conditions. As an example, the method is applied to the case of sequential synthesis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.