Abstract

In many highly glazed buildings, the thermal comfort of the occupants will tend to be related to the incoming solar energy and the heat transfer behaviour of the glazing. In this study, several glazing systems were designed using the software tools VISION 3 (University of Waterloo 1992) and WINDOW-6 (Lawrence Berkeley National Laboratory 2011), with a view to improving thermal environment of occupants near the glazed wall of a commercial office. The systems were fabricated and experimentally tested to validate the software modelling results. Subsequently, the glazing systems were retro-fitted to the office and tested in situ for a summer month. Results of this testing, in the form of Fangers’ predicted mean vote (PMV) and the predicted percentage dissatisfied (PPD), are presented, and some options for improving the thermal environment in this near-façade zone are discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.