Abstract
Lightweight curtain wall systems and precast concrete wall panels are commonly used in steel skeleton external wall construction. The design of external wall components must incorporate modular-dimensional coordination rules. Modular design of external walls reduces component types and increases the buildability of façades. The purpose of this study is to research the adaptability of large standard precast wall panels to steel skeleton structures according to the modular coordination rules. In addition, according to the possible locations of the wall panels in the façades, design dimensions are calculated and types of panels are recommended in conclusion.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.