Abstract
AbstractWe designed a screen‐printed gold electrode (SPGE) with a peptide to detect cancer cells. The ability to sense circulating tumor cells (CTCs) and monitor their movement in blood vessels is important for cancer diagnosis. Human monocytic leukemia cells were selected as a model of CTCs because of their origin. The cell‐recognition and cell‐sensing peptide moieties were EICADP and Y4C. The SPGE was modified with the cell‐recognition moieties of the CY4EICADPY4C in a bridge‐type construction due to the cysteine residue at both terminals. The calibration curve was linear and ranged from 25 to 2,000 cells/mL with a LOD of 8 cells/mL.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.