A 60 T nondestructive pulsed magnet for the "Free Electron Laser for Infrared Experiments" (FELIX) is developed. As a rise time of 10 /spl mu/s is required, the magnet is designed consisting of two coils in order to cope with the skin effect and power requirements. Each of the coils is energized by its own capacitor bank. The inner coil is composed of 2 helices made from copper tubes; it is energized by a 12 kV, 0.1 mF capacitor bank to generate 30 T with 20 /spl mu/s pulse duration. The 60 T field is obtained by adding a 30 T field from the outer coil with 5 ms pulse duration energized by a 5 kV, 8 mF capacitor bank. The basic design criteria, the coil modeling and manufacturing techniques are discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.