Extensive studies have already been carried out by other workers on the CIE Standard Overcast Sky and the Clear Blue Sky as daylighting design skies for temperate regions and other areas in the hot, dry tropics. The present study reports on the partly cloudy or cloudy skies prevalent in the warm, humid tropics and proposes a design sky for this region. For daylighting design in the humid tropics a completely overcast sky is proposed whose average zenith luminance is 7 000 cd m-2 with a corresponding average total illuminance of 17 000 lux from an unobstructed sky. These values are compared with those by other workers.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.