Abstract
AbstractThis paper presents a design approach for calculating rectangular hollow section (RHS) splices (bolted end plate connections) under tension forces or bending moments in accordance with EN 1993‐1‐8. Based on models available in the literature, a Eurocode‐conform model is presented using the component method. The original model, based on experimental and numerical investigations, uses a three‐dimensional yield line method to predict the tension resistance of bolted splices with hollow sections considering the joint as a whole. The adapted model is fully compatible with EN 1993‐1‐8. Moreover, the original model has been extended to predict also the design moment resistance of such RHS splices.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.