Abstract
Design considerations of the intense positron facility being setup at Research reactor at Bhabha Atomic Research Center is presented here. A thin sheet of cadmium will convert the intense thermal neutron flux present near reactor core to a high energy gamma ray flux. These gamma rays will cause electron positron pair production in tungsten mesh assembly which are placed close by. These convertor tungsten mesh assembly are designed to have high surface area and they will act as moderators too thus emitting the slow positrons. GEANT and FLUKA Monte Carlo codes are used to optimize the design parameters of the cadmium sheet and the tungsten mesh assembly. A final intensity close to 2×109 e+/sec is predicted for this facility
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.