Abstract

Abstract This paper aims to develop design methods for the shear strength of welded stainless steel I-shaped members. The current American AISC Design Guide 27 has been published for Structural Stainless Steel, and it refers to the specification ANSI/AISC 360-16 for structural steel buildings for the shear strength without considering tension field action (TFA). All the available test data on stainless steel plate girders were collected from literatures and employed to assess the provisions in the Design Guide 27, as well as the codified ones in Eurocode 3 Part 1.4. Based on the test results and obtained comparisons, two new proposals for unstiffened webs or webs with transverse stiffeners widely spaced (without TFA), and for interior webs with stiffeners spaced at 3hw or smaller (considering TFA) were developed and presented to match the format of the expressions in ANSI/AISC 360-16 for stainless steel webs under shear. Reliability analysis was further performed to calculate the Load and Resistance Factor Design (LRFD) resistance factors determined by the new proposals and to further justify the target factor in AISC Design Guide 27 for structural stainless steel.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.