Abstract

In this study, we proposed governing equations for voice coil type linear actuator for valve operation. We draw up governing equations which are composed by combination of electromagnetic theories and empirical knowledge, and deduct the values of major design factors by use of them. We suggested the governing equations to determine the values of design parameters of linear actuator as like bobbin size, length of yoke and plunger and turn number of coil. And we also calculated the life test time of linear actuator for verification of reliability of the prototype. In addition, for reducing the life test time, the acceleration model of linear actuator is proposed and the acceleration factor is calculated considering the field operating conditions. Finally we have proven the propriety of the governing equations by accelerated life test using the valve assembly adopted the voice coil type linear actuator prototype.