Abstract

A new external superconducting (SC) bus-line system consisting of 13 pairs of bus-lines has been designed for the upgrade project of the experimental advanced SC tokamak. The old system integrated into two vacuum ducts will be extended approx. 23 m with new cable in conduit conductors (CICCs) connecting by twin-box lap joints. The leakage currents of the CICCs electrically insulated with four layers of polyimide films and pre-impregnation fiberglass tapes are <10 μA under a 10 kV electrical potential at 77 K, 0.1–100 Pa in helium atmosphere. Each bus-line pair is bound together by 50 % overwrapped with three layers of Kevlar polyester tapes to eliminate its adverse effects of electromagnetic forces with a maximum of 2.44 kN/m. The bus-lines designed with at least four bends are flexible to absorb the thermal shrinkage which is approx. 90 mm in total. The maximum shift of the CICCs is 26.1 mm when cooled down. The total thermal loads to 5 K components in bus-line group 1 and 2 are <0.3 W/m as required.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call