Abstract

New and high transparent structural element, steel-glass composite beam was developed in respect to fabrication, static-structural and architectural criteria and consists of steel flanges and glass web assembled together by semi-rigid polymer adhesive, which is the key element of whole composite system. These beams can be used mainly as members of high transparent roof or floor structure as well as stiffening fins for large area glass facades. This paper deals with experimental research performed at CTU (Czech Technical University) Prague, which started by adhesive selection and initial material tests by ISO527, continued via small-scale steel-glass connection tests and graduated by full-scale tests of hybrid beams with the span of 4 m. Generalized results of these experiments, analytical and numerical studies serve as device, how to accurately predict the behavior of the beam, describe the stress distribution along the cross section and safely and economically design such a kind of structure with semi-rigid shear connection, made by polymer adhesive.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call