Abstract
In the ITER Core Plasma Thomson Scattering, the scattered light collection optics system is installed both inside and outside the diagnostic port under vacuum. The length of the optical path (∼6 m) and the need to shield the neutron and γ radiation increased the complexity of the system with the inclusion of multiple dog-legs, forcing the use of many elements with optical power. Multiple rounds of design have been required in order to satisfy iteratively the system requirements in terms of resolution, aberration, and shielding. The adoption of quasi-free-form reflective surfaces for several mirrors eventually allowed the correct compromise between all conflicting requirements.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.