<p>Non-structural components are sensitive to large floor accelerations, velocities, and displacements. When a building is subjected to an earthquake ground motion, it can amplify this motion, resulting in Peak Floor Accelerations (PFAs) higher than the Peak Ground Acceleration. A 4-storey reinforced concrete building is designed in accordance with EC8. The building is supposed to have in its interior, at a particular floor level (ideally located in the middle of the considered floor), some special facilities which need to not receive either big accelerations or high relative storey displacements. New types of Lead-Rubber Bearing based storey-isolation systems are here developed, investigating five different facilities isolation locations. The intent is to demonstrate the isolation positive effects on the facilities through non-linear time-history analyses, and to evaluate the global structure effects: PFAs, Peak Floor Displacements (PFDs) and interstorey drift ratios.</p>

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.