Abstract
A soft X ray (SXR) imaging system for diagnosing magnetic islands of a reversed field pinch (RFP) plasma is proposed. The SXR imaging system utilizes a microchannel plate (MCP) to record a higher-resolution distribution of two-dimensional (2D) luminosity on a phosphor plate. In order to identify the structure of the magnetic island from the obtained SXR image, we have calculated the 2D image expected from RFP plasmas. It is found that the 2D image reflects the change in the radiation intensity caused by the magnetic island. Also, the magnetic island can be distinguished clearly when the radiation power emitted from the magnetic island is more than about 20 % of that on the magnetic axis of RFP. Regarding with the view angle α of the SXR imaging system, the magnetic island due to a tearing mode on the m = 1/n = 8 rational surface can be detected as far as α > π/10.
Published Version (Free)
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.