To improve the reliability of the light emitting diode (LED) signal lamp filament current monitoring alarm instrument for metro systems, a new type of hot standby online monitoring apparatus was developed which is based on synchronous transmission data (STD) bus technology. In this system, a double hot standby mode can be achieved by adopting bus arbitration. In addition, to detect the effective value of alternating current which is from 0 to 200 mA in the signal lamp lighting circuit, a precision rectifier signal conditioning circuit and an isolated acquisition circuit were designed. This new type of alarm instrument has high detection accuracy and could meet the functional requirements for metro signal systems after comparing it with some industry products that were applied on the spot.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.