Abstract

A computational fluid dynamics (CFD) model is presented and applied in the design of the secondary settling tanks of Psyttalia Wastewater Treatment Plant in Athens, Europe’s largest sewage treatment facility. The tanks are of the Gould Type II consisting of the following regions: an inlet-flocculation chamber with an inlet baffle, two zones of settling separated by an intermediate baffle, an outlet region, and a sludge collection region. The number of tanks and their dimensions were determined with an empirical design procedure. Then, theoretical considerations, information from similar existing tanks, and preliminary CFD calculations were combined to determine the dimensions of the main regions and the positions of the baffles. Finally, detailed CFD calculations were performed to examine the performance of the tanks for various design conditions. Computations showed that the flow in the inlet-flocculation region was completely mixed; while in the settling regions a “three-layer” structure with relatively...