Abstract

In this study, a reduced size neutron long counter with improved response function was designed using SuperMC simulation code. The main parts of the reduced size long counter are 3He proportional counter, cylindrical moderators made of polyethylene, chromium metal converter, neutron absorber material and outer aluminum cover. A 1.5 cm thick layer of chromium metal was embedded into the hydrogen-rich moderator to enhance response of the long counter at high neutron energies. The radius and length of the long counter was reduced to 15 cm and 35 cm, respectively. In this design we managed to obtain a flat response function from a few keV to 20 MeV energy range. The angular response function, determined at 0.5 MeV and 14 MeV neutron energies, confirmed that the reduced size long counter designed in this study is not significantly affected by in-scattered neutrons. The reduced size long counter is suitable for use as a standard transfer instrument for monitoring neutron fluence in mono-energetic neutron fields.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.