Abstract

A computer code for the design of optical sensors is developed, the electromagnetic model taking into account both lossy guided and leaky modes. For a concentration C = 700 ppm of toluene in water, the maximum absorbance of a sensor having length L=2 cm is A ≡ 10 for the guided quasi-TM00 mode, while that pertaining to the leaky quasi-TM12 mode is A ≈ 1200. The simulation results indicate that a selective excitation of the suitable propagation modes could enhance the sensor performance.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.