Abstract

In order to study the generation and extraction of negative ions for neutral beam injection application, a prototype radio frequency driven negative ion source and the corresponding test bench are under construction at the Institute of Plasma Physics, Chinese Academy of Sciences. A new design of infrared radiation diagnostic calorimeter for testing beam characteristics is put forward. Compared with the conventional calorimeter, the calorimeter adopts the block structure (8 × 28 tungsten hexahedron blocks) and modularization design (4 modules), so it has higher precision and good scalability. The thermal performance of the calorimeter is assessed using a finite element method. Simulation results show that the design can be achieved to operate in the stable-state mode at the maximum thermal flux 6.45 MW/m2 and meet the full requirement of beam diagnosis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.