Abstract

Impedance measuring circuits play a crucial role in an electrical impedance tomography system, in which capacitance and resistance need to be measured accurately at a high speed. Several impedance measuring circuits based on phase-sensitive demodulation (PSD) have been designed, tested, and presented in this paper. The measurement error is analyzed, and the mismatch of the measured capacitance and resistance is considered to be the main cause of the measurement error. A new impedance measuring circuit with dual-frequency PSD has been designed to solve this problem. It has been proven by experiment that this circuit can be used to measure both capacitance and resistance with an uncertainty of less than 0.5%.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.