Abstract

A grid-connected parallel inverter with interleaved phase shift is proposed in this paper. The synchronous are generated by the master module to achieve interleaving phase shift PWM for the parallel inverters connected to grid-tied system that make the inverter to output current to the power line and share the load. TI TMS320F2812 DSP is used for system feedback control with voltage and current by using A/D converters to generate the output current close to sine wave. The expected output current values are determined by the master module and transmitted via CAN (Control area network) between inverter modules. The grid-tied system uses zero-voltage-detection circuit to synchronize the inverter currents with grid voltage. For each switching period, PWM voltage of two inverters are interleaved to reduce the total output current ripple so that the switching frequency can be reduced and the power system EMI problem can be alleviated as well. The experiment results are provided to verify the performance of the proposed system to reduce output current harmonic distortion.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.