In this paper, a method to design the two-channel FIR linear-phase (LP) face-centred orthorhombic (FCO) filter banks with equiripple magnitude responses and perfect-reconstruction (PR) is presented. The necessary conditions of lengths of LP FCO filter banks satisfying the PR constraint are derived. An interior-point algorithm is utilized to optimize the peak ripples of the analysis filters and a first-order approximation skill is introduced to satisfy the PR constraint. The simulation example is presented to illustrate the effectiveness of this proposed design technique.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.