Abstract

The core and edge Thomson systems on Korea Superconducting Tokamak Advanced Research employ two different sets of lens collection optics. Their collection systems are positioned in the front end of a long reentrant cassette for optimum viewing coverage and optical throughput. Both systems collect the scattered light from a single tangential beam of multiple 50-Hz Nd:YAG lasers and image the scattering volume from core to edge with 40 spatial points. In order to obtain a higher resolution of 5 mm, the edge system has more spatial channels than the core system. Pressure-free heat shield windows, which will absorb the radiation heat flux, are mounted in front of large vacuum windows to protect them from the radiation heat load during long-pulse discharges.