Abstract
During the test of DC(direct current) abrasive magnetic fluid technology,many bubbles and noises were generated near the graphite electrode , and the yellow green liquid was produced, which affected the further test.Through the study of graphite electrode, it was found that NaCl solution magnetic fluid produced hydrogen and chlorine gas after electrolysis. At the same time, chlorine gas dissolved in water to form yellow green liquid.The magnetic field of neodymium boron permanent magnet was equivalent to a mechanical stirring, which inhibited the production of chlorine gas.According to the difference of impressed current system, the abrasive magnetic fluid jet technology was divided into DC and AC(alternating current) .There was no electrode in AC abrasive magnetic fluid jet technology, so no gas or noise would be produced.The rotating magic ring permanent magnet produced alternating magnetic field, acting on the abrasive magnetic fluid to form an induced current.Under the action of the magnetic field, the electromagnetic force was applied to move along the circumferential direction to promote the motion of the abrasive magnetic fluid.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.