Abstract
An effective method, adaptive fuzzy sliding-mode (SM) PI Control to design full-bridge inverter is proposed in this paper. For practical applications, sliding mode control (SMC) with chattering phenomenon is a large hindrance. The modified model of the PI controller is built by the plant extension scheme, in order to relieve the chattering. Also, the fuzzy logic is applied to find the appropriate parameter values of the PI controller, and can adapt to plant parameter variations and external load disturbances. The proposed method has been realized for the actual full-bridge inverters controlled by DSP and CPLD. Simulation and experimental results of the closed-loop system show that the proposed method yields system performance improvement, such as low total harmonic distortion (THD), fast dynamic response, reduced steady-state error, and reduced chattering.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.