Abstract

AbstractIn the literature, many control charts monitoring the median is designed under a perfect condition that there is no measurement error. This may make the practitioners confusing to apply these control charts because the measurement error is the true problem in practice. In this paper, we consider the effect of measurement error on the performance of the exponentially weighted moving average (EWMA) control chart combining with the variable sampling interval (VSI) strategy. A linear covariate error model is supposed to model the measurement error. The performance of the VSI EWMA median control chart is evaluated through the average time to signal. The numerical simulation shows that the measurement errors have a negative influence on the proposed chart.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.